BJWBM - M100 PEMCO ADHESIVE 1599
- MSDS: BJWBM
- Manufacturer: PEMCO ADHESIVES INC
- Product Name: M100 PEMCO ADHESIVE 1599
- National Stock Number: 2640-00-922-6921
Product Identification
Product ID:M100 PEMCO ADHESIVE 1599
MSDS Date:01/01/1987
FSC:2640
NIIN:00-922-6921
MSDS Number: BJWBM
Responsible Party
Emergency Phone: (219) 925-3368
Info Phone: (219) 925-3368
Cage: OPES8
Contractor
Telephone: (219) 925-3368
Cage: OPES8
Ingredients
RUBBER
ACGIH TLV: 350 PPM
RESIN
METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 85%
OSHA PEL 350 PPM/450 STEL
ACGIH TLV: 350 PPM/450STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: MILD IRRITATION. SKIN: DEFATTING
& MILD IRRITATION. INHALATION: ANESTHETIC EFFECT 500 TO 10 PPM.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYE: MILD IRRITATION. SKIN: DEFATTING & MILD
IRRITATION. INHALATION: ANESTHETIC EFFECT.
First Aid
First Aid:SKIN/EYES: FLUSH W/WATR FOR 15 MINUTES. INHALATION: REMOVE TO
FRESH AIR. KEEP WARM & QUIET. IF BREATHING IS STOPPED, GIVE
ARTIFICIAL RESPIRATION. OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Extinguishing Media:SELF-EXTINGUISHING
Fire Fighting Procedures:SELF CONTAINED RESPIRATORY EQUIPMENT.
Accidental Release
Spill Release Procedures:MOP UP, TREAT W/ABSORBANT, AREA BURY ABSORBED
MATERIAL. KEEP AWAY FROM WATER SUPPLY & INHABITED BLDGS.
Handling
Handling and Storage Precautions:AVOID BREATHING VAPORS.
Exposure Controls
Ventilation:LOCAL EXHAUST VENTILATION TO KEEP
Eye Protection:SAFETY GLASSES W/SIDES SHIELD
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:165F
Vapor Pres:100
Vapor Density:4.55
Spec Gravity:1.321
Evaporation Rate & Reference:(BU AC = 1): 6
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS LIQUID W/ETHER ODOR.
Percent Volatiles by Volume:100%
Stability
Stability Indicator/Materials to Avoid:YES
WATER-SLOW HYDROLYSIS PRODUCES HYDROGEN CHLORIDE
Stability Condition to Avoid:HIGH TEMPERATURE OR OPEN FLAME
Hazardous Decomposition Products:HYDROGEN CHLORIDE, PHOSGENE, CHLORINE
Disposal
Waste Disposal Methods:BURY AWAY FROM WATER SUPPLY & ALLOW TO EVAPORATE
AWAY FROM PEOPLE & INHABITED BUILDINGS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.